主页 文献库文献详情
PMID: 10984458 已发表 · ppublish 英语

Rapid detection of deletion, insertion, and substitution mutations via heteroduplex analysis using capillary- and microchip-based electrophoresis.

Genome research ·第 10 卷 ·第 9 期 ·2000-10-17

Tian H, Brody L C, Landers J P

摘要

In this report, we explore the potential of capillary and microchip electrophoresis for heteroduplex analysis- (HDA) based mutation detection. Fluorescent dye-labeled primers (6-FAM-tagged) were used to amplify the DNA fragments ranging from 130 to 400 bp. The effects of DNA fragment length, matrix additives, pH, and salt were evaluated for capillary electrophoresis- (CE) and/or microchip electrophoresis-based HDA, using six heterozygous mutations, 185delAG, E1250X (3867GT), R1443G (4446CG), 5382insC, 5677insA in BRCA1, and 6174delT in BRCA2. For this system, the effective fragment size for CE-based HDA was found in the range of 200-300 bp, however, the effective range was 150-260 bp for microchip-based HDA. Sensitivity studies show CE-based HDA could detect a mutated DNA present at only 1%-10% of the total DNA. Discrimination between wild-type and deletion or insertion mutations in BRCA1 and BRCA2 with CE-based HDA could be achieved in <8 min, while the substitution mutations required 14 min of analysis time. For each mutation region, 15 samples were run to confirm the accuracy and reproducibility of the method. Using the method described, two previously reported mutations, E1038G (3232AG, missense) and 4427 C/T (4427CT, polymorphism), were detected in the tested samples and confirmed by DNA sequencing. Translation of the CE-based methodology to the microchip format allowed the analysis time for each mutation to be decreased to 130 sec. Based on the results obtained with this model system, it is possible that CE-based HDA methodologies can be developed and used effectively in genetic testing. The fast separation time and automated operation afforded with CE instrumentation provide a powerful system for screening mutations that include small deletions, insertions, and point mutations. Translation to the microchip platform, especially to a multichannel microchip system, would allow for screening mutations with high throughput.

文献信息
期刊
Genome research
期刊简称
Genome Res
发表日期
2000-10-17
收录日期
2000-10-17
更新日期
2015-11-19
语言
英语
国家/地区
United States
NLM ID
9518021
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: product@genelibs.com