主页 文献库文献详情
PMID: 14583097 已发表 · epublish 英语

Performance of high-throughput DNA quantification methods.

BMC biotechnology ·第 3 卷 ·2004-05-26

Haque Kashif A, Pfeiffer Ruth M, Beerman Michael B, Struewing Jeff P, Chanock Stephen J, Bergen Andrew W

摘要

The accuracy and precision of estimates of DNA concentration are critical factors for efficient use of DNA samples in high-throughput genotype and sequence analyses. We evaluated the performance of spectrophotometric (OD) DNA quantification, and compared it to two fluorometric quantification methods, the PicoGreen assay (PG), and a novel real-time quantitative genomic PCR assay (QG) specific to a region at the human BRCA1 locus. Twenty-Two lymphoblastoid cell line DNA samples with an initial concentration of approximately 350 ng/uL were diluted to 20 ng/uL. DNA concentration was estimated by OD and further diluted to 5 ng/uL. The concentrations of multiple aliquots of the final dilution were measured by the OD, QG and PG methods. The effects of manual and robotic laboratory sample handling procedures on the estimates of DNA concentration were assessed using variance components analyses.,The OD method was the DNA quantification method most concordant with the reference sample among the three methods evaluated. A large fraction of the total variance for all three methods (36.0-95.7%) was explained by sample-to-sample variation, whereas the amount of variance attributable to sample handling was small (0.8-17.5%). Residual error (3.2-59.4%), corresponding to un-modelled factors, contributed a greater extent to the total variation than the sample handling procedures.,The application of a specific DNA quantification method to a particular molecular genetic laboratory protocol must take into account the accuracy and precision of the specific method, as well as the requirements of the experimental workflow with respect to sample volumes and throughput. While OD was the most concordant and precise DNA quantification method in this study, the information provided by the quantitative PCR assay regarding the suitability of DNA samples for PCR may be an essential factor for some protocols, despite the decreased concordance and precision of this method.

文献信息
期刊
BMC biotechnology
期刊简称
BMC Biotechnol
发表日期
2004-05-26
收录日期
2004-05-10
更新日期
2016-12-03
语言
英语
国家/地区
England
NLM ID
101088663
分析服务
分析服务

联系地址

山东省济南市章丘区文博路2号

齐鲁师范学院 genelibs生信实验室

山东省济南市高新区舜华路750号

大学科技园北区F座4单元2楼

电话: 0531-88819269

微信公众号

关注微信订阅号,实时查看信息,关注医学生物学动态。


商务邮箱

E-mail: product@genelibs.com