Home LiteratureArticle Details
PMID: 16014550 Published · ppublish English

Evaluation of a novel line-blot immunoassay for the detection of antibodies to extractable nuclear antigens.

Damoiseaux J, Boesten K, Giesen J, Austen J, Tervaert J W Cohen

Abstract

We have evaluated the performance of a novel line-blot immunoassay (LIA; Mikrogen) and compared results with those obtained by CIE (in-house), ELISA (Pharmacia Diagnostics), and FEIA (Pharmacia Diagnostics). Sera from systemic lupus erythematosus (SLE) patients (n = 123), systemic sclerosis patients (n = 25), and healthy controls (n = 40) were analyzed for the presence of antibodies to RNP, Sm, SSA, SSB, CENP-B, Scl-70, and Jo-1. Reading of LIA results, as compared with a cutoff control, was performed by automatic analysis of the test strips. Because LIA enables recognition of separate subunits of RNP (68, A, and C), Sm (B and D), and SSA (52 and 60), at least two of the RNP antigens and either one of the Sm or SSA antigens should be detected for considering the test RNP, Sm, or SSA-positive, respectively. LIA had the highest sensitivity in patients with autoimmune connective tissue diseases: 131 specificities (not PO, PCNA, or histones), as compared with ELISA (121), FEIA (119), and CIE (80). However, LIA revealed three positive reactions in healthy controls; other assays were completely negative. LIA is better than CIE, but similar to ELISA and FEIA, in terms of detecting systemic sclerosis-associated antibodies (CENP-B and Scl-70). Furthermore, LIA had the highest sensitivity (17.9%) for the SLE-specific anti-Sm antibodies, as compared with ELISA (11.4%), CIE (8.1%), and FEIA (5.7%). Finally, anti-SSA antibodies were far more prevalent by LIA in the systemic sclerosis samples because of anti-SSA52 reactivity. The clinical relevance of the latter finding remains to be determined. In conclusion, LIA is suitable for routine evaluation of autoantibodies to extractable nuclear antigens.

Article Info
Journal
Annals of the New York Academy of Sciences
Abbr.
Ann N Y Acad Sci
Published
2005-10-19
Indexed
2005-07-14
Updated
2008-11-21
Language
English
Country/Region
United States
NLM ID
7506858
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com