Home LiteratureArticle Details
PMID: 18356243 Published · ppublish English

Screening autoantibody profiles in systemic rheumatic disease with a diagnostic protein microarray that uses a filtration-assisted nanodot array luminometric immunoassay (NALIA).

Clinical chemistry ·Vol. 54 ·No. 5 ·2008-05-00 ·页码 883-90

McBride JD, Gabriel FG, Fordham J, Kolind T, Barcenas-Morales G, Isenberg DA, Swana M, Delves PJ, Lund T, Cree IA, Roitt IM

Abstract

We developed a cost-efficient modular system for multiplex analysis of the multiple autoantibodies that characterize systemic rheumatoid diseases. The nanodot array luminometric immunoassay (NALIA) system consists of conventional 96-well membrane-bottomed plates in which antigens or antibodies are adsorbed onto the underside of the membrane. Current arrays use a 5 x 5 format (25 dots/well), which allows 10 analytes to be measured in duplicate: double-stranded DNA (dsDNA), centromere protein B (CENP-B), PCNA, Sm, Sm ribonucleoprotein (Sm-RNP), U1-snRNP, Scl70, SSA/Ro, SSB/La, Jo-1, and controls. The test fluid, control sera, and subsequent reagents are drawn through the membrane. The captured analytes are quantified by monitoring chemiluminescence with a charge-coupled device (CCD) and analyzed with commercial array software. The assay can detect <20 x 10(3) IU/L of anti-dsDNA. The interwell CV was 10%-14%. There was an 83% concordance (kappa = 0.56) between the NALIA results obtained for anti-dsDNA assayed by beta-testing in a routine immunology diagnostic laboratory and the results obtained with a conventional ELISA reagent set. The concordance values for Ro, La, Sm, and RNP were 98% (kappa, 0.92), 93% (kappa, 0.41), 97% (kappa, 0.62), and 97% (kappa, 0.73), respectively. The NALIA approach promises to provide a highly economical platform for a wide range of applications that require assays of multiple analytes. The degree of concordance of our results with a conventional reagent set was no less than that occurring between different commercial products. A sample of serum from a finger stick provides a volume sufficient to perform the array assay.

Article Info
Journal
Clinical chemistry
Abbr.
Clin Chem
ISSN
0009-9147
Published
2008-05-00
电子出版
2008-00-20
页码
883-90
Language
English
Country/Region
England
NLM ID
9421549
Analysis Services
Analysis Services

Contact

No. 2 Wenbo Road, Zhangqiu District, Jinan, Shandong

Qilu Normal University · Genelibs Bioinformatics Lab

750 Shunhua Rd, Jinan

2F, Bldg F, University Science Park

Tel: 0531-88819269

WeChat Official Account

Follow our WeChat subscription account for real-time updates and the latest in medical and biological research.


Business Email

E-mail: product@genelibs.com